Barcode Settings

Contents

Barcode Settings#

Symbology#

All Symbologies#

If the code reading device needs to read all symbologies, please scan the “All symbologies enabled” barcode. To only read a specific symbology, please scan the “All symbologies disabled” barcode, and then scan the enable barcode for that specific symbology.

../../_shared/_images/module-320/9990011..png

All encodings enabled#

../../_shared/_images/module-320/9990010..png

All encodings disabled#

Note

After scanning the “All symbologies enabled” barcode, 2D postal codes are not enabled by default. 2D postal codes must be enabled separately.

Reading length description#

The effective reading length of certain Symbologies can be set. If the length of the barcode data read does not match the effective reading length, the code reading device will issue an error tone. Setting the minimum and maximum length to the same value will force the barcode reading device to read fixed-length barcodes. This helps reduce misreadings.

Example

Only barcodes with a length of 6-10 characters are read.

Minimum length=06. Maximum length=10

  1. Select the Symbology for which you want to set the maximum and minimum reading length, scan the “Minimum Reading Length” barcode under its directory, scan the number “6” barcode and the “Save” barcode from Appendix Charts.

  2. Scan the “Maximum Read Length” barcode, scan the digits “1”, “0” and “Save” barcodes from Appendix Charts.

The above steps will set the maximum reading length of the selected Symbology to 10 and the minimum reading length to 6.

1D Symbologies#

If the code reading device needs to read all 1D barcodes, please scan the “All 1D barcodes enabled” barcode. Only certain Symbologies can be read, please scan the “All 1D Symbologies disabled” barcode.

../../_shared/_images/module-320/9950040..png

* All 1D symbologies enabled#

../../_shared/_images/module-320/9950041..png

All one-dimensional Symbologies disabled#

2D Symbologies#

If the code reading device needs to read all barcode systems, please scan the “All QR Symbologies enabled” barcode. Only certain Symbologies can be read, please scan the “All QR Symbologies Disabled” barcode.

../../_shared/_images/module-320/9950070..png

* All QR Symbologies enabled#

../../_shared/_images/module-320/9950071..png

All QR codes are disabled#

Codabar#

Note

Default all Codabar settings

../../_shared/_images/module-320/900000..png

Restore Codabar default settings#

Enable/disable#

../../_shared/_images/module-320/9000031..png

* Enable#

../../_shared/_images/module-320/9000030..png

Disable#

start/stop characters#

“Start/Stop” character output is located at the leading and trailing ends of the barcode. Configurable to transmit or not transmit Start/Stop characters. Default = no transmission.

../../_shared/_images/module-320/9000061..png

transmission#

../../_shared/_images/module-320/9000060..png

* Do not transmit#

Check character#

No check characters means that the barcode reading device will read and transmit all barcodes with or without check characters. (When scanning a barcode with check characters at this time, the check characters are transmitted together)

When “Check Character” is set to “Enable, do not transmit check characters”, the code reading device will verify based on the last digit of the barcode. If the verification passes, normal data except the last check character will be transmitted. If the verification fails, the barcode content will not be sent.

When “Check Character” is set to “Enable, transmit check character”, the code reading device will verify based on the last digit of the barcode. If the verification passes, the check character will be transmitted together with the last digit of normal data. If the verification fails, the barcode content will not be sent.

../../_shared/_images/module-320/9000010..png

* No check character#

../../_shared/_images/module-320/9000011..png

Enable, do not transmit check characters#

../../_shared/_images/module-320/9000012..png

Enable, transmit check characters#

cascade#

Codabar supports barcode concatenation. When cascading is enabled, the barcode reading device looks for a Codabar barcode with a “D” start character that is adjacent to a barcode with a “D” stop character. In this case, the two barcodes are concatenated into one, omitting all “D” characters.

A 1 2 3 4 D D 5 6 7 8A

Scan the “Require” barcode to prevent barcode reading devices from decoding a single “D” Codabar barcode without an adjacent “D” starting character for the Codabar barcode. This selection has no effect on Codabar without stop/start D characters.

../../_shared/_images/module-320/9000021..png

Enable#

../../_shared/_images/module-320/9000022..png

need#

../../_shared/_images/module-320/9000020..png

* Disable#

Reading length#

Scan the barcode below to change the reading length. For additional information, see Reading length description. Minimum and maximum lengths are 2-60. Minimum default value=4, maximum default value=60. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/900005..png

Minimum reading length#

../../_shared/_images/module-320/900004..png

Maximum reading length#

Code 39#

Enable/disable#

../../_shared/_images/module-320/9010011..png

* Enable#

Note

Default Code 39 configuration

../../_shared/_images/module-320/901000..png

Restore Code 39 default settings#

../../_shared/_images/module-320/9010010..png

Disable#

start/stop characters#

“Start/stop characters” are located at the beginning and end of the barcode. Configurable to transmit or not transmit “start/stop characters”. Default = no transmission.

../../_shared/_images/module-320/9010091..png

transmission#

../../_shared/_images/module-320/9010090..png

* Do not transmit#

Check character#

No check characters means that the barcode reading device will read and transmit all barcodes with or without check characters. (When scanning a barcode with check characters at this time, the check characters are transmitted together)

When “Check Character” is set to “Enable, do not transmit check characters”, the code reading device will verify based on the last digit of the barcode. If the verification passes, normal data except the last check character will be transmitted. If the verification fails, the barcode content will not be sent.

When “Check Character” is set to “Enable, transmit check character”, the code reading device will verify based on the last digit of the barcode. If the verification passes, the check character will be transmitted together with the last digit of normal data. If the verification fails, the barcode content will not be sent.

../../_shared/_images/module-320/9010040..png

* No check character#

../../_shared/_images/module-320/9010041..png

Enable, do not transmit check characters#

../../_shared/_images/module-320/9010042..png

Enable, transmit check characters#

Reading length#

Scan the barcode below to change the reading length. For additional information, see Reading length description. Minimum and maximum lengths are 0-48. Minimum default value=0, maximum default value=48. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/901008..png

Minimum reading length#

../../_shared/_images/module-320/901007..png

Maximum reading length#

Code 32 Pharmaceutical (PARAF)#

Code 32 Pharmaceutical is a form of the Code 39 barcode used in Italian pharmacies. When configuring Code 32, you need to enable Code 39 before configuring it.

This encoding is also called PARAF.

../../_shared/_images/module-320/9010051..png

Enable#

../../_shared/_images/module-320/9010050..png

* Disable#

FULL ASCII#

If Code 39 Full ASCII decoding is enabled, some characters in the barcode will be decoded into single characters.

Example

$V will be decoded to the ASCII character SYN and /C will be decoded to the ASCII character #. Default = disabled.

NUL%U

DLE $P

SP SPACE

0/P

@%V

P P

‘ %W

p+P

SOH$A

DC1 $Q

!/A

1/Q

A A

Q Q

a+A

q+Q

STX$B

DC2 $R

“/B

2/R

B B

R R

b+B

r+R

ETX$C

DC3$S

# /C

3/S

C C

S S

c+C

s+S

EOT $D

DC4 $T

$ /D

4/T

D D

T T

d+D

t+T

ENQ $E

NAK $U

% /E

5/U

E E

U U

e+E

u+U

ACK $F

SYN$V

& /F

6/V

F F

V V

f+F

v+V

BEL$G

ETB $W

‘/G

7/W

G G

W W

g+G

w+W

BS$H

CAN$X

(/H

8/X

H H

X

h+H

x+X

HT $I

EM$Y

) /I

9/Y

I I

Y Y

i+I

y+Y

LF$J

SUB$Z

*/J

:/Z

J J

Z Z

j+J

z+Z

VT$K

ESC %A

+ /K

; %F

K K

[ %K

k+K

{ %P

FF$L

FS%B

, /L

< %G

L L

\ %L

l+L

| %Q

CR$M

GS%C

-/M

=%H

M M

] %M

m+M

} %R

SO$N

RS %D

./N

> %I

N N

^%N

n+N

~%S

SI$O

US%E

/ /O

?%J

O O

_ %O

o +O

DEL%T

The character pairs /M and /N are decoded as a minus sign and a period respectively. Character pairs /P to /Y are decoded as 0 to 9.

../../_shared/_images/module-320/9010031..png

FULL ASCII enabled#

../../_shared/_images/module-320/9010030..png

* FULL ASCII disabled#

Interleaved 2 of 5#

Note

Default all Interleaved 2 of 5 settings

../../_shared/_images/module-320/902000..png

Restore Interleaved 2 of 5 default settings#

Enable/disable#

../../_shared/_images/module-320/9020021..png

* Enable#

../../_shared/_images/module-320/9020020..png

Disable#

Check character#

No check characters means that the barcode reading device will read and transmit all barcodes with or without check characters. (When scanning a barcode with check characters at this time, the check characters are transmitted together)

When “Check Character” is set to “Enable, do not transmit check characters”, the code reading device will verify based on the last digit of the barcode. If the verification passes, normal data except the last check character will be transmitted. If the verification fails, the barcode content will not be sent.

When “Check Character” is set to “Enable, transmit check character”, the code reading device will verify based on the last digit of the barcode. If the verification passes, the check character will be transmitted together with the last digit of normal data. If the verification fails, the barcode content will not be sent.

../../_shared/_images/module-320/9020010..png

* No check character#

../../_shared/_images/module-320/9020011..png

Enable, do not transmit check characters#

../../_shared/_images/module-320/9020012..png

Enable, transmit check characters#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 2-80. Minimum default value=4, maximum default value=80. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/902004..png

Minimum reading length#

../../_shared/_images/module-320/902003..png

Maximum reading length#

NEC 2of5#

Enable/disable#

Note

Default all NEC 2 of 5 settings

../../_shared/_images/module-320/903000..png

Restore NEC 2 of 5 default settings#

../../_shared/_images/module-320/9030011..png

* Enable#

../../_shared/_images/module-320/9030010..png

Disable#

Check character#

No check characters means that the barcode reading device will read and transmit all barcodes with or without check characters. (When scanning a barcode with check characters at this time, the check characters are transmitted together)

When “Check Character” is set to “Enable, do not transmit check characters”, the code reading device will verify based on the last digit of the barcode. If the verification passes, normal data except the last check character will be transmitted. If the verification fails, the barcode content will not be sent.

When “Check Character” is set to “Enable, transmit check character”, the code reading device will verify based on the last digit of the barcode. If the verification passes, the check character will be transmitted together with the last digit of normal data. If the verification fails, the barcode content will not be sent.

../../_shared/_images/module-320/9030020..png

* No check character#

../../_shared/_images/module-320/9030021..png

Enable, do not transmit check characters#

../../_shared/_images/module-320/9030022..png

Enable, transmit check characters#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 2-80. Minimum default value=4, maximum default value=80. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/903004..png

Minimum reading length#

../../_shared/_images/module-320/903003..png

Maximum reading length#

Code 93#

Note

Default all Code 93 settings

../../_shared/_images/module-320/904000..png

Restore Code 93 default settings#

Enable/disable#

../../_shared/_images/module-320/9040021..png

* Enable#

../../_shared/_images/module-320/9040020..png

Disable#

Reading length#

Scan the barcode to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 0-80. Minimum default value=0, maximum default value=80. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/904004..png

Minimum reading length#

../../_shared/_images/module-320/904003..png

Maximum reading length#

Straight 2 of 5 Industrial (three-bar start/stop)#

Note

Restore Straight 2 of 5 Industrial default settings

../../_shared/_images/module-320/905000..png

Restore Straight 2 of 5 Industrial default settings#

Enable/disable#

../../_shared/_images/module-320/9050011..png

Enable#

../../_shared/_images/module-320/9050010..png

* Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-48. Minimum default value=4, maximum default value=48. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/905003..png

Minimum reading length#

../../_shared/_images/module-320/905002..png

Maximum reading length#

Straight 2 of 5 IATA (two-bar start/stop)#

Note

Restore Straight 2 of 5 IATA default settings

../../_shared/_images/module-320/906000..png

Restore Straight 2 of 5 IATA default settings#

Enable/disable#

../../_shared/_images/module-320/9060011..png

Enable#

../../_shared/_images/module-320/9060010..png

* Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-48. Minimum default value=4, maximum default value=48. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/906003..png

Minimum reading length#

../../_shared/_images/module-320/906002..png

Maximum reading length#

Matrix 2 of 5#

Note

Defaults to all Matrix 2 of 5 settings

../../_shared/_images/module-320/907000..png

Restore Matrix 2 of 5 default settings#

Enable/disable#

../../_shared/_images/module-320/9070011..png

Enable#

../../_shared/_images/module-320/9070010..png

* Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-80. Minimum default value=4, maximum default value=80. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/907003..png

Minimum reading length#

../../_shared/_images/module-320/907002..png

Maximum reading length#

Check#

This option sets the enabling and disabling of the Matrix 2 of 5 code verification function.

../../_shared/_images/module-320/9070051..png

Enable verification#

../../_shared/_images/module-320/9070050..png

* Disable validation#

Code 11#

Note

Default all settings

../../_shared/_images/module-320/908000..png

Restore Code 11 default settings#

Enable/disable#

../../_shared/_images/module-320/9080021..png

Enable#

../../_shared/_images/module-320/9080020..png

* Disable#

Check Digit#

This option sets 1 or 2 check digits for Code 11 barcodes. Default = two check digits.

../../_shared/_images/module-320/3110280..png

a check digit#

../../_shared/_images/module-320/3110281..png

* Two check digits#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-80. Minimum default value=4, maximum default value=80. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/908004..png

Minimum reading length#

../../_shared/_images/module-320/908003..png

Maximum reading length#

Code 128#

Note

Default all Code 128 settings

../../_shared/_images/module-320/909000..png

Restore Code 128 default settings#

Enable/disable#

../../_shared/_images/module-320/9090011..png

* Enable#

../../_shared/_images/module-320/9090010..png

Disable#

ISBT 128 cascade#

../../_shared/_images/module-320/9020051..png

ISBT 128 Enable#

../../_shared/_images/module-320/9020050..png

* ISBT 128 disabled#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 0-80. Minimum default value=0, maximum default value=80. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/909003..png

Minimum reading length#

../../_shared/_images/module-320/909002..png

* Maximum reading length#

GS1-128#

Note

Default all GS1-128 settings

../../_shared/_images/module-320/910000..png

Restore GS1-128 default settings#

Enable/disable#

../../_shared/_images/module-320/9100011..png

* Enable#

../../_shared/_images/module-320/9100010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-80. Minimum default value=1, maximum default value=80. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/910003..png

Minimum reading length#

../../_shared/_images/module-320/910002..png

Maximum reading length#

UPC-A#

Note

Default all UPC-A settings

../../_shared/_images/module-320/912000..png

Restore UPC-A default settings#

Enable/disable#

../../_shared/_images/module-320/9120031..png

* Enable#

../../_shared/_images/module-320/9120030..png

Disable#

Check Digit#

The following configures whether a check digit should be transmitted at the end of the output data. Default = enabled.

../../_shared/_images/module-320/9120041..png

* Enable#

../../_shared/_images/module-320/9120040..png

Disable#

digital system#

UPC numeric system characters are usually transmitted at the beginning of the output data, default = enabled.

../../_shared/_images/module-320/9120051..png

* Enable#

../../_shared/_images/module-320/9120050..png

Disable#

Additional code#

This setting adds a two-digit or five-digit additional code to the end of all read UPC-A data.

Default=2/5 digit add-on code disabled.

../../_shared/_images/module-320/9120011..png

2-digit add-on code enabled#

../../_shared/_images/module-320/9120010..png

* 2-digit appendix disabled#

../../_shared/_images/module-320/9120021..png

5-digit add-on code enabled#

../../_shared/_images/module-320/9120020..png

* 5-digit appendix disabled#

Required add-on code#

When “Required” is scanned, the barcode reading device will only read UPC-A barcodes with the add-on code. Then, you must enable the 2 or 5 digit add-on code. Default=not required.

../../_shared/_images/module-320/9120061..png

need#

../../_shared/_images/module-320/9120060..png

* unnecessary#

Additional code separator#

When this function is enabled, there will be a space separating the barcode and the additional code. When disabled, no space separation occurs. Default = enabled.

../../_shared/_images/module-320/9120071..png

* Enable#

../../_shared/_images/module-320/9120070..png

Disable#

Note

UPC-A can be converted to EAN-13 with the following setup code

../../_shared/_images/module-320/9120111..png

Not turning#

../../_shared/_images/module-320/9120110..png

change#

UPC-E0#

Note

Default all UPC-E settings

../../_shared/_images/module-320/914000..png

Restore UPC-E default settings#

Enable/disable#

Most UPC barcodes start with the 0 digit system. To read these barcodes, scan the “*UPC-E0 Enabled” barcode. If you need to read barcodes using the 1 digit system, please scan “UPC-E1 Enable”. Default=UPC-E0 enabled.

../../_shared/_images/module-320/9140101..png

* UPC-E0 enabled#

../../_shared/_images/module-320/9140100..png

UPC-E0 disabled#

barcode extension#

UPC-E Expand expands UPC-E barcodes into 12-digit UPC-A format. Default = disabled.

../../_shared/_images/module-320/9140021..png

Enable#

../../_shared/_images/module-320/9140020..png

* Disable#

Required add-on code#

When “Required” is scanned, the barcode reading device will only read UPC-E barcodes with additional codes. Default = Not required.

../../_shared/_images/module-320/9140031..png

need#

../../_shared/_images/module-320/9140030..png

* unnecessary#

Additional code separator#

When this function is enabled, there will be a space separating the barcode and the additional code. When disabled, no space separation occurs. Default = enabled.

../../_shared/_images/module-320/9140041..png

* Enable#

../../_shared/_images/module-320/9140040..png

Disable#

Check Digit#

The following configures whether a check digit should be transmitted at the end of the output data. Default = enabled.

../../_shared/_images/module-320/9140051..png

* Enable#

../../_shared/_images/module-320/9140050..png

Disable#

digital system#

The numeric system characters of UPC are usually transmitted at the beginning of the output data. Default = enabled.

../../_shared/_images/module-320/9140061..png

* Enable#

../../_shared/_images/module-320/9140060..png

Disable#

Additional code#

This setting adds a 2/5-digit additional code to the end of all read UPC-E data. Default=2/5 digit add-on code disabled.

../../_shared/_images/module-320/9140071..png

2-digit add-on code enabled#

../../_shared/_images/module-320/9140070..png

* 2-digit appendix disabled#

../../_shared/_images/module-320/9140081..png

5-digit add-on code enabled#

../../_shared/_images/module-320/9140080..png

* 5-digit appendix disabled#

UPC-E1#

Most UPC barcodes start with the 0 digit system. To read these barcodes, scan the “*UPC-E0 Enabled” barcode. If you need to read barcodes using the 1 digit system, please scan “UPC-E1 Enable”. Default=UPC-E1 disabled.

../../_shared/_images/module-320/9140091..png

UPC-E1 enabled#

../../_shared/_images/module-320/9140090..png

*UPC-E1 disabled#

EAN/JAN-13#

Note

Default all EAN/JAN settings

../../_shared/_images/module-320/915000..png

Restore EAN/JAN-13 default settings#

Enable/disable#

../../_shared/_images/module-320/9150011..png

* Enable#

../../_shared/_images/module-320/9150010..png

Disable#

Note

If you want to convert a UPC-A barcode to EAN-13 format, scan the UPC-A disabled barcode.

Check Digit#

The following configures whether a check digit should be transmitted at the end of the output data. Default = enabled.

../../_shared/_images/module-320/9150021..png

* Enable#

../../_shared/_images/module-320/9150020..png

Disable#

Additional code#

This setting adds a 2/5-digit additional code to the end of all read EAN/JAN-13 data.

Default=2/5 digit add-on code disabled.

../../_shared/_images/module-320/9150031..png

2-digit add-on code enabled#

../../_shared/_images/module-320/9150030..png

* 2-digit appendix disabled#

../../_shared/_images/module-320/9150041..png

5-digit add-on code enabled#

../../_shared/_images/module-320/9150040..png

* 5-digit appendix disabled#

Required add-on code#

When scanning “Required”, the code reading device will only read EAN/JAN-13 barcodes with additional codes. Default=not required.

../../_shared/_images/module-320/9150051..png

need#

../../_shared/_images/module-320/9150050..png

* unnecessary#

Additional code separator#

When this function is enabled, there will be a space separating the barcode and the additional code. When disabled, no space separation occurs. Default = enabled.

../../_shared/_images/module-320/9150061..png

* Enable#

../../_shared/_images/module-320/9150060..png

Disable#

ISBN Translate#

When set to be transmitted in ISBN symbols, EAN-13 Bookland symbols will be converted to the equivalent ISBN symbol format. Default = disabled.

../../_shared/_images/module-320/9150071..png

Enable#

../../_shared/_images/module-320/9150070..png

* Disable#

EAN/JAN-8#

Note

Default all EAN/JAN-8 settings

../../_shared/_images/module-320/916000..png

Restore EAN/JAN-8 default settings#

Enable/disable#

../../_shared/_images/module-320/9160011..png

* Enable#

../../_shared/_images/module-320/9160010..png

Disable#

Check character#

The following configures whether a check character should be transmitted at the end of the output data. Default = enabled.

../../_shared/_images/module-320/9160021..png

* Enable#

../../_shared/_images/module-320/9160020..png

Disable#

Additional code#

This setting adds a 2/5-digit additional code to the end of all read EAN/JAN-13 data.

Default=2/5 digit add-on code disabled

../../_shared/_images/module-320/9160031..png

2-digit add-on code enabled#

../../_shared/_images/module-320/9160030..png

* 2-digit appendix disabled#

../../_shared/_images/module-320/9160030.-2.png

5-digit add-on code enabled#

../../_shared/_images/module-320/9160041..png

5-digit add-on code enabled#

../../_shared/_images/module-320/9160040..png

* 5-digit appendix disabled#

Required add-on code#

When scanning “Required”, the code reading device will only read EAN/JAN-8 barcodes with additional codes. Default=not required.

../../_shared/_images/module-320/9160051..png

need#

../../_shared/_images/module-320/9160050..png

* unnecessary#

Additional code separator#

When this function is enabled, there will be a space separating the barcode and the additional code. When disabled, no space separation occurs. Default = enabled.

../../_shared/_images/module-320/9160061..png

* Enable#

../../_shared/_images/module-320/9160060..png

Disable#

MSI#

Note

Default all MSI settings

../../_shared/_images/module-320/917000..png

Restore MSI default settings#

Enable/disable#

../../_shared/_images/module-320/9170011..png

Enable#

../../_shared/_images/module-320/9170010..png

* Disable#

Check character#

MSI barcodes use different types of check characters. You can configure your barcode reading device to read MSI barcodes using check characters. Default = MOD10 enabled, but no transmission.

When “Check Character” is set to “Enable MOD10 and Transmit”, the barcode reading device will only read and use MSI barcodes printed with the specified type of check characters, and will transmit the characters at the end of the output data.

When “Check Character” is set to “Enable MOD10, but do not transmit”, the device will only read and use MSI barcodes printed with the specified type of check characters, but will not transmit scanned check characters.

../../_shared/_images/module-320/9170020..png

* Enable MOD10, but do not transmit#

../../_shared/_images/module-320/9170021..png

Enable MOD10 and transmit#

../../_shared/_images/module-320/9170026..png

Disable MSI check characters#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 4-48. Minimum default value=4, maximum default value=48. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/917004..png

Minimum reading length#

../../_shared/_images/module-320/917003..png

Maximum reading length#

GS1 DataBar Omnidirectional#

Note

Defaults to all GS1 DataBar Omnidirectional settings

../../_shared/_images/module-320/918000..png

Restore GS1 DataBar Omnidirectional default settings#

Enable/disable#

../../_shared/_images/module-320/9180011..png

* Enable#

../../_shared/_images/module-320/9180010..png

Disable#

GS1 DataBar Limited#

Note

Defaults to all GS1 DataBar Limited settings

../../_shared/_images/module-320/919000..png

Restore GS1 DataBar Limited default settings#

Enable/disable#

../../_shared/_images/module-320/9190011..png

* Enable#

../../_shared/_images/module-320/9190010..png

Disable#

GS1 DataBar Expanded#

Note

Default all settings

../../_shared/_images/module-320/920000..png

Restore GS1 DataBar Expanded default settings#

Enable/disable#

../../_shared/_images/module-320/9200011..png

* Enable#

../../_shared/_images/module-320/9200010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 4-74. Minimum default value=4, maximum default value=74. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/920003..png

Minimum reading length#

../../_shared/_images/module-320/920002..png

Maximum reading length#

PDF417#

Note

Default all PDF417 settings

../../_shared/_images/module-320/924000..png

Restore PDF417 default settings#

Enable/disable#

../../_shared/_images/module-320/9240011..png

* Enable#

../../_shared/_images/module-320/9240010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-2750. Minimum default value=1, maximum default value=2750. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/924003..png

Minimum reading length#

../../_shared/_images/module-320/924002..png

Maximum reading length#

QR Code#

Note

Default all QR Code settings

../../_shared/_images/module-320/928000..png

Restore QR Code and Micro QR Code default settings#

Enable/disable#

../../_shared/_images/module-320/9280011..png

* Enable#

../../_shared/_images/module-320/9280010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. The minimum and maximum lengths are 1-7089. Minimum default value=1, maximum default value=7089. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/928003..png

Minimum reading length#

../../_shared/_images/module-320/928002..png

Maximum reading length#

Data Matrix#

Note

Default all Data Matrix settings

../../_shared/_images/module-320/930000..png

Restore Data Matrix default settings#

Enable/disable#

../../_shared/_images/module-320/9300011..png

* Enable#

../../_shared/_images/module-320/9300010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. The minimum and maximum length are 1-3116. Minimum default value=1, maximum default value=3116. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/930003..png

Maximum reading length#

Minimum reading length

../../_shared/_images/module-320/930002..png

Maximum reading length#

Aztec Code#

Note

Default all Aztec Code settings

../../_shared/_images/module-320/931000..png

Restore Aztec Code default settings#

Enable/disable#

../../_shared/_images/module-320/9310011..png

* Enable#

../../_shared/_images/module-320/9310010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. The minimum and maximum lengths are 1-3832. Minimum default value=1, maximum default value=3832. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/931003..png

Minimum reading length#

../../_shared/_images/module-320/931002..png

Maximum reading length#

China Post (Hong Kong 2 of 5)#

Note

Defaults to all China Post (Hong Kong 2 of 5) settings

../../_shared/_images/module-320/936000..png

Restore China Post default settings#

Enable/disable#

../../_shared/_images/module-320/9360011..png

Enable#

../../_shared/_images/module-320/9360010..png

* Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 2-80. Minimum default value=4, maximum default value=80. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/936003..png

Minimum reading length#

../../_shared/_images/module-320/936002..png

Maximum reading length#

Korea Post#

Note

Default all settings

../../_shared/_images/module-320/937000..png

Restore Korea Post default settings#

Enable/disable#

../../_shared/_images/module-320/9370011..png

Enable#

../../_shared/_images/module-320/9370010..png

* Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 2-80. Minimum default value=4, maximum default value=48. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/937003..png

Minimum reading length#

../../_shared/_images/module-320/937002..png

Maximum reading length#

Check Digit#

Scan the following barcode to determine whether a check digit should be transmitted at the end of the output data. Default = disabled.

../../_shared/_images/module-320/9370041..png

Enable#

../../_shared/_images/module-320/9370040..png

* Disable#

Han Xin Code#

Enable/disable#

../../_shared/_images/module-320/9320011..png

Enable#

Note

Default all Han Xin settings

../../_shared/_images/module-320/932000..png

Restore Han Xin Code default settings#

../../_shared/_images/module-320/9320010..png

* Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-1000. Minimum default value=1, maximum default value=1000. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/932003..png

Minimum reading length#

../../_shared/_images/module-320/932002..png

Maximum reading length#

MaxiCode#

Note

Default all MaxiCode settings

../../_shared/_images/module-320/929000..png

Restore MaxiCode default settings#

Enable/disable#

../../_shared/_images/module-320/9290011..png

Enable#

../../_shared/_images/module-320/9290010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-150. Minimum default value=1, maximum default value=150. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/929003..png

Minimum reading length#

../../_shared/_images/module-320/929002..png

Maximum reading length#

Micropdf#

Note

Default all micropdf settings

../../_shared/_images/module-320/925000..png

Restore MicroPDF417 default settings#

Enable/disable#

../../_shared/_images/module-320/9250011..png

Enable#

../../_shared/_images/module-320/9250010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. The minimum and maximum length are 1-366. Minimum default value=1, maximum default value=366. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/925003..png

Minimum reading length#

../../_shared/_images/module-320/925002..png

Maximum reading length#

GS1 Composite Code#

Note

Default settings for all composites

../../_shared/_images/module-320/926000..png

Restore GS1 Composite Code default settings#

Enable/disable#

../../_shared/_images/module-320/9260011..png

Enable#

../../_shared/_images/module-320/9260010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. The minimum and maximum lengths are 1-2435. Minimum default value=1, maximum default value=2435. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/926004..png

Minimum reading length#

../../_shared/_images/module-320/926003..png

Maximum reading length#

Codablock A#

Note

Default settings for all composites

../../_shared/_images/module-320/922000..png

Restore Codablock A default settings#

Enable/disable#

../../_shared/_images/module-320/9220011..png

Enable#

../../_shared/_images/module-320/9220010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. Minimum and maximum lengths are 1-600. Minimum default value=1, maximum default value=600. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/922003..png

Minimum reading length#

../../_shared/_images/module-320/922002..png

Maximum reading length#

Codablock F#

Note

Default settings for all composites

../../_shared/_images/module-320/923000..png

Restore Codablock F default settings#

Enable/disable#

../../_shared/_images/module-320/9230011..png

Enable#

../../_shared/_images/module-320/9230010..png

Disable#

Reading length#

Scan the barcode below to change the read length. For additional information, see Reading length description. The minimum and maximum lengths are 1-2048. Minimum default value=1, maximum default value=2048. (Note: After scanning the “minimum reading length” and “maximum reading length”, you need to scan the specified reading length and save the barcode, please refer to Reading length description)

../../_shared/_images/module-320/923003..png

Minimum reading length#

../../_shared/_images/module-320/923002..png

Maximum reading length#