Barcode Settings#
Setup Instructions#
Each symbology has its own unique attributes. Through the code setting in this chapter, the Scan Engine can be adjusted to adapt to these attribute changes. The fewer symbologies with “Allow Reading” enabled, the faster the Scan Engine will read. You can disable the Scan Engine from reading unused symbologies to improve the performance of the Scan Engine.
EAN/UPC symbology Settings#
EAN-8#
Enable/disable#
* Enable EAN-8#
Disable EAN-8#
Check Digit Transmission#
EAN-8 data contains 8 digits. The 8th digit is the check digit, which validates the first 7 digits. By default, the check digit is transmitted; you can disable its transmission.
* Send Check Digit#
No Check Digit Sent#
EAN-8 Hide Leading Characters#
* EAN-8 Does Not Hide Leading Characters#
Supplemental Decode#
Enable 2-digit Add-on Code#
Enable 5-digit Add-on Code#
Enable 2-digit And 5-digit Add-on Codes#
* Disable Additional Codes#
Force Additional Code To Be Enabled#
EAN-13#
Enable/disable#
* Enable EAN-13#
Disable EAN-13#
Redundancy#
Enable UPC/EAN Redundancy#
* Disable UPC/EAN Redundancy#
*UPC/EAN Security Level 0#
UPC/EAN Security Level 1#
Check Digit Transmission#
EAN-13 data contains 13 digits. The 13th digit is the check digit, which validates the first 12 digits. By default, the check digit is transmitted; you can disable its transmission.
* Send Check Digit#
No Check Digit Sent#
Leading Character Transmission#
* EAN-13 Send Leading Character#
EAN-13 Does Not Send Leading Characters#
Supplemental Decode#
Enable 2-digit Add-on Code#
Enable 5-digit Add-on Code#
Enable 2-digit And 5-digit Add-on Codes#
* Disable Additional Codes#
Force Additional Code To Be Enabled#
EAN-13 Convert to ISBN#
ISBN is a book code, and 13-digit data is normally output. When EAN-13 to ISBN is enabled, the output is a 10-digit ISBN code. Conversion is disabled by default.
Enable EAN-13 To ISBN#
* Disable EAN-13 To ISBN#
EAN-13 Convert to ISSN#
ISSN is a magazine code, which normally outputs 13-digit data. When EAN-13 to ISBN is enabled, the output is a 10-digit ISSN code. Conversion is disabled by default.
Enable EAN-13 To ISSN#
Disable EAN-13 To ISSN#
UPC-A#
Enable/disable#
* Enable UPC-A#
Disable UPC-A#
Check Digit Transmission#
UPC-A data contains 12 digits. The 12th digit is the check digit, which validates the first 11 digits. By default, the check digit is transmitted; you can disable its transmission.
* Send Check Digit#
No Check Digit Sent#
Leading Character Transmission#
UPC-A Hides Leading Characters#
UPC-A Does Not Hide Leading Characters#
Supplemental Decode#
Enable 2-digit Add-on Code#
Enable 5-digit Add-on Code#
Enable 2-digit And 5-digit Add-on Codes#
* Disable Additional Codes#
Force Additional Code To Be Enabled#
UPC-A To EAN-13#
Users can set whether they need to convert UPC-A to EAN-13 output according to their needs. The default is not to convert.
Enable UPC-A To EAN-13#
* Disable UPC-A To EAN-13#
UPC-E#
Enable/disable#
* Enable UPC-E#
Disable UPC-E#
Supplemental Decode#
Enable 2-digit Add-on Code#
Enable 5-digit Add-on Code#
Enable 2-digit And 5-digit Add-on Codes#
* Disable Additional Codes#
Force Additional Code To Be Enabled#
UPC-E To UPC-A#
Users can set whether they need to convert UPC-E to UPC-A output according to their needs. The default is not to convert.
Enable UPC-E To UPC-A#
* Disable UPC-E To UPC-A#
Check Digit Transmission#
UPC-E Does Not Send Check Digits#
UPC-E Sends Check Digit#
Commonly Used 1D Barcode Settings#
Codabar (Cudabarcode)#
Enable/disable#
* Enable Codabar#
Disable Codabar#
Start/Stop Character Transmission#
Enable Codabar Start and Stop Characters#
* Disable Codabar Start and Stop Characters#
Set Codabar Minimum Length 4#
- Parameter Format
0087hhhhTwo hexadecimal digits used to set the Codabar minimum length.
Code 11#
Enable/disable#
* Enable Code 11#
Disable Code 11#
- Parameter Format
0128hhhhTwo hexadecimal numbers used to set the Code 11 minimum length.
Code 39#
Enable/disable#
* Enable Code 39#
Disable Code 39#
Check Digit Transmission#
Verification Settings#
Disable Code 39 Verification#
Enable Code 39 MOD43 Verification#
* Disable Code 39 MOD43 check#
Redundancy#
* Disable Code 39 Redundancy#
Enable Code 39 Redundancy#
Start/Stop Character Transmission#
Code 39 uses an asterisk (“*”) as both its start and stop character. You can configure whether these characters are transmitted with the barcode data after a successful read.
Enable Code 39 Start and Stop Characters#
* Disable Code 39 Start and Stop Characters#
Full ASCII Support#
The encoding method of Code 39 can include the representation of all ASCII characters. Through settings, the Scan Engine can support barcodes containing the full ASCII character set.
* Enable Full ASCII Support#
Disable Full ASCII Support#
Code 32 Settings#
* Disable Code 32#
Enable Code 32#
* Disable Code 32 Prefix A#
Enable Code 32 Prefix A#
Code 39 length setting#
Set The Minimum Length Of Code 39 To 1#
* Set the minimum length of Code 39 to 2#
Code 93#
Enable/disable#
* Enable Code 93#
Disable Code 93#
Redundancy#
Enable Code 93 Redundancy#
* Disable Code 93 Redundancy#
Code 128#
Enable/disable#
* Enable Code 128#
Disable Code 128#
Redundancy#
* Disable Code 128 Redundancy#
Enable Code 128 Redundancy#
Brazilian Banking Model#
Enable Brazilian Banking Mode (Code 128)#
Disable Brazilian Banking Mode (Code 128)#
GS1 DataBar symbology Settings#
GS1 DataBar Limited (RSS Limited)#
Enable/disable#
Enable RSS Limited#
* Disable RSS Limited#
GS1 DataBar Omnidirectional (RSS Omnidirectional)#
Enable/disable#
Enable RSS Omnidirectional#
* Disable RSS Omnidirectional#
GS1 DataBar Expanded (RSS Expanded)#
Enable/disable#
Enable GS1 DataBar Expanded#
* Disable GS1 DataBar Expanded#
2 Of 5 Types Of Code Settings#
Interleaved 2 of 5 (interleaved 25 yards)#
Enable/disable#
* Enable Interleaved 25-code#
Disable Crossover 25 Codes#
Redundancy#
* Disable cross-25 Code Redundancy#
Enable cross-25 Multi-pass Verification#
Length Setting#
Set Cross 25 Yard Minimum Length 4#
Brazilian Banking Model#
Enable Banking Mode#
Disable Banking Mode#
Industrial 2 of 5 (Industrial 25 yards)#
Enable/disable#
* Enable Industrial 25 Code#
Disable Industrial 25 Code#
Length Setting#
Set Industrial 25 Yard Minimum Length 3#
Matrix 2 of 5 (matrix 25 codes)#
Enable/disable#
Enable Matrix 25 Codes#
* Disable Matrix 25 Codes#
Length Setting#
Set Matrix 25 Code Minimum Length 2#
Other 1D Barcode Settings#
China Post#
Enable/disable#
* Disable China Post Code#
Enable China Post Code#
MSI#
Enable/disable#
Enable MSI Code#
* Disable MSI Code#
* Do Not Transmit MSI Check Digit#
Transmit MSI Check Digit#
Redundancy#
* Disable MSI Redundancy#
Enable MSI Redundancy#
Length Setting#
Set MSI Minimum Length 3#
Plessey/Telepen#
Enable/disable#
Enable Plessey Code#
* Disable Plessey Code#
Length Setting#
Set Plessey/Telepen minimum length 3#